29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
    29 Liter Class B white autoclave with USB and integrated printer
    29 Liter Class B white autoclave with USB and integrated printer
    29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
    29 Liter Class B white autoclave with USB and integrated printer
    29 Liter Class B white autoclave with USB and integrated printer
    29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer
29 Liter Class B white autoclave with USB and integrated printer

Product information

Description

White 29-liter Class B Autoclave with USB and Integrated Printer

Warranty details

Safety
- It is essential that the water quality is below 20 microsiemens for the autoclave to start cycles.

- The cycle will not start if the door is not properly closed.
- The automated double hydraulic interlocking safety device prevents the door from opening while the chamber is under pressure.
- Safety valves prevent pressure generator and camera.
- A safety thermostat prevents overheating in the chamber and generator.
- An automatic safety lock prevents accidental opening of the door during the sterilization process; the protector automatically cuts off electrical power if there is a short circuit or the power supply is unstable.
- Fault alarm indicates a failed cycle and detailed error code.
- Door alarm indicates that the door is not secured.
- Low water alarm indicates when the water tank is empty or too full.

Technical Specifications
- Voltage: 220-240 VAC; 50/60 Hz; 10A
- External dimensions of the device: W x H x L: 490 x 455 x 860 mm
- Tray dimensions: #1. 185x570 mm #2. 213x570 mm #3. 227x570 mm
- Circuit breaker: F16A / 400V
- Rated power: 1500 VA
- 2300W
- Sterilization temperature: 121 ° C / 134 ° C
- Distilled water tank capacity: 2.5 L
- Operating temperature: 5 ° C / 40
- Relative humidity: Max. 80%, non-condensing
- Net weight: 65 kg
- Maximum noise level: <70 dB
- Atmospheric pressure from 76 kPa / 106 kPa

Icanclave Autoclave: maintenance and error message guide

Components
- Distilled water tank
- LCD screen
- Control panel
- Main switch
- Key for draining distilled and used water
- USB port
- Internal printer (allows printing sterilization cycle reports on thermal paper after the cycle ends.)
- Safety valve
- Ventilation grille
- Locking system
- Power cable
- Label

Included accessories
- Sterilizer
- USB
- 3 instrument trays
- Tray support
- Handle for tray extraction
- Door adjustment tool
- 2 drain hoses
- Door gasket
- Instruction manual

Regulations
- 93/42 / CEE Medical devices directive.
- 97/23 / CEE Pressure equipment directive.
- EN 13060 Small steam sterilizers.
- EN 61326, EN 61000 EMC.
- EN 61010-1, UL 61010-1 safety requirements.
- EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.

Autoclave step-by-step process
1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.

2. Connect the power cord to a suitable power source.

3. Connect the printer.

4. Power on: the main switch is located on the front, bottom right of the device. Once switched on, the LCD screen will light up, and the basic operating symbols of the sterilizer, such as door position, water level, sterilization program, date, and time, will light up.

5. Remove the top cover then fill the distilled water tank. If a beeping sound is heard, it means you have exceeded the permitted water level in the tank. Drain the excess water until the alarm stops.

6. Preparation of material for sterilization: place the instruments on the different trays, separating them according to their materials. If the instruments are not stainless steel, use sterilization pouches. These should not be in contact. Check that all instruments are properly placed so that no water remains in hollow parts. Do not overload the instrument trays and do not place them in direct contact with the sterilization chamber walls. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.

7. Select the sterilization program.

8. Start the sterilization cycle.
After selecting the sterilization program, place the instruments on the trays in the chamber using the supplied plastic tongs.
Once the instruments are properly placed inside, close the door. Precaution: make sure to close the door properly, otherwise the sterilizer will not be able to operate.

9. Start the sterilization program.
Press the start button, the autoclave will begin operating for approximately 30-75 minutes.

10. End of sterilization cycle.
Once the sterilization cycle is complete, the printer will automatically print the full cycle report.
Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will notify you with an audible signal once the sterilization cycle is complete.
Precaution: Use plastic tongs to remove the instruments.

IMPORTANT: Do not reuse used water after draining the tank.

 

It is important to keep the original packaging in case of after-sales service.

Program

Temp.

/Pressure

Sterilization time Total time (min)
8D Pro 12D Pro

18D Pro

23D Pro
QUICK 134 134℃/210Kpa 3.5 min 10-20 11-20 12-30 15-30
WRAPPED 134 134℃/210Kpa 4 min 25-40 28-45 30-49 38-57
WRAPPED 121 121℃/110Kpa 20 min 36-46 37-48 38-54 46-62
PRION 134 134℃/210Kpa 18 min 35-46 36-48 37-52 45-60
B&D TEST 134 3.5 min 10-20 15-25 15-30 28-35
HELIX TEST 134 3.5 min 10-20 15-25 15-30 28-35
VACUUM TEST 17-20 18-21 19-22 20-25

* Cycle duration is based on different loads and with/without preheating.

* Sterilization time and drying time can be adjusted.

 

Description

White 29-liter Class B Autoclave with USB and Integrated Printer

Warranty details

Safety
- It is essential that the water quality is below 20 microsiemens for the autoclave to start cycles.

- The cycle will not start if the door is not properly closed.
- The automated double hydraulic interlocking safety device prevents the door from opening while the chamber is under pressure.
- Safety valves prevent pressure generator and camera.
- A safety thermostat prevents overheating in the chamber and generator.
- An automatic safety lock prevents accidental opening of the door during the sterilization process; the protector automatically cuts off electrical power if there is a short circuit or the power supply is unstable.
- Fault alarm indicates a failed cycle and detailed error code.
- Door alarm indicates that the door is not secured.
- Low water alarm indicates when the water tank is empty or too full.

Technical Specifications
- Voltage: 220-240 VAC; 50/60 Hz; 10A
- External dimensions of the device: W x H x L: 490 x 455 x 860 mm
- Tray dimensions: #1. 185x570 mm #2. 213x570 mm #3. 227x570 mm
- Circuit breaker: F16A / 400V
- Rated power: 1500 VA
- 2300W
- Sterilization temperature: 121 ° C / 134 ° C
- Distilled water tank capacity: 2.5 L
- Operating temperature: 5 ° C / 40
- Relative humidity: Max. 80%, non-condensing
- Net weight: 65 kg
- Maximum noise level: <70 dB
- Atmospheric pressure from 76 kPa / 106 kPa

Icanclave Autoclave: maintenance and error message guide

Components
- Distilled water tank
- LCD screen
- Control panel
- Main switch
- Key for draining distilled and used water
- USB port
- Internal printer (allows printing sterilization cycle reports on thermal paper after the cycle ends.)
- Safety valve
- Ventilation grille
- Locking system
- Power cable
- Label

Included accessories
- Sterilizer
- USB
- 3 instrument trays
- Tray support
- Handle for tray extraction
- Door adjustment tool
- 2 drain hoses
- Door gasket
- Instruction manual

Regulations
- 93/42 / CEE Medical devices directive.
- 97/23 / CEE Pressure equipment directive.
- EN 13060 Small steam sterilizers.
- EN 61326, EN 61000 EMC.
- EN 61010-1, UL 61010-1 safety requirements.
- EN 61010-2-040, IEC 61010-2-040 Particular requirements for steam sterilizers used for the treatment of medical materials.

Autoclave step-by-step process
1. Open the door, take out the tools and accessories from the sterilization chamber, remove the packaging and clean them.

2. Connect the power cord to a suitable power source.

3. Connect the printer.

4. Power on: the main switch is located on the front, bottom right of the device. Once switched on, the LCD screen will light up, and the basic operating symbols of the sterilizer, such as door position, water level, sterilization program, date, and time, will light up.

5. Remove the top cover then fill the distilled water tank. If a beeping sound is heard, it means you have exceeded the permitted water level in the tank. Drain the excess water until the alarm stops.

6. Preparation of material for sterilization: place the instruments on the different trays, separating them according to their materials. If the instruments are not stainless steel, use sterilization pouches. These should not be in contact. Check that all instruments are properly placed so that no water remains in hollow parts. Do not overload the instrument trays and do not place them in direct contact with the sterilization chamber walls. Do not use paper clips or needles to avoid any damage or malfunction of the autoclave.

7. Select the sterilization program.

8. Start the sterilization cycle.
After selecting the sterilization program, place the instruments on the trays in the chamber using the supplied plastic tongs.
Once the instruments are properly placed inside, close the door. Precaution: make sure to close the door properly, otherwise the sterilizer will not be able to operate.

9. Start the sterilization program.
Press the start button, the autoclave will begin operating for approximately 30-75 minutes.

10. End of sterilization cycle.
Once the sterilization cycle is complete, the printer will automatically print the full cycle report.
Once the pressure has dropped to 0, you can open the door and remove the instruments. The autoclave will notify you with an audible signal once the sterilization cycle is complete.
Precaution: Use plastic tongs to remove the instruments.

IMPORTANT: Do not reuse used water after draining the tank.

 

It is important to keep the original packaging in case of after-sales service.

Program

Temp.

/Pressure

Sterilization time Total time (min)
8D Pro 12D Pro

18D Pro

23D Pro
QUICK 134 134℃/210Kpa 3.5 min 10-20 11-20 12-30 15-30
WRAPPED 134 134℃/210Kpa 4 min 25-40 28-45 30-49 38-57
WRAPPED 121 121℃/110Kpa 20 min 36-46 37-48 38-54 46-62
PRION 134 134℃/210Kpa 18 min 35-46 36-48 37-52 45-60
B&D TEST 134 3.5 min 10-20 15-25 15-30 28-35
HELIX TEST 134 3.5 min 10-20 15-25 15-30 28-35
VACUUM TEST 17-20 18-21 19-22 20-25

* Cycle duration is based on different loads and with/without preheating.

* Sterilization time and drying time can be adjusted.

 

Marque : Icanclave Autoclaves  |  Référence : 49.018

29 Liter Class B white autoclave with USB and integrated printer

In short
Class B 29 Litre White Autoclave with USB backup and integrated printer.Double hydraulic locking ...  Read more
Regular price
4.456,83€
Sale price
4.456,83€
Regular price
6.856,67€
Tax included. Shipping calculated at checkout.
🚚 Disponible immédiatement

Disponibilité : actualisez la page une fois la variante sélectionnée pour mettre à jour la disponibilité

Secure Payment: Visa, MasterCard, Amex, Apple Pay
Free delivery from 100€ purchase including tax
Delivery to your office, to a relay point or to your home!

Référence My Podologie : Translation missing: en.products.product.sku:49.018
EAN :

Garantie : 1 year
Caractéristiques : Non spécifiées
Mentions particulières : Photos non contractuelles

Check out these similar products